blueprint:
name: CO₂ ventilation alert – Apollo R PRO-1 (LED + buzzer)
description: >-
Visual and audible CO₂ alerts on an Apollo R PRO-1.
**LED**: off below the "ventilation recommended" level. From that level
it turns yellow and fades towards red as CO₂ approaches the "ventilation
needed" level; at or above it, it is solid red.
**Buzzer**: at or above the "start beeping" level the beep action is
repeated at the chosen interval, but only while CO₂ is NOT dropping.
"Dropping" means the newest CO₂ reading is lower than the reading about
one minute earlier (taken from a Statistics helper, see the
"CO₂ change" input). Beeping stops as soon as CO₂ is falling, at any level.
domain: automation
input:
co2_sensor:
name: CO₂ sensor
description: The R PRO-1 CO₂ sensor (ppm).
selector:
entity:
filter:
- domain: sensor
device_class: carbon_dioxide
change_sensor:
name: CO₂ change over the last minute
description: >-
A Statistics helper based on the CO₂ sensor above. Settings: State
characteristic = "Change", Max age = 1 minute (use 90 s if your
sensor reports slower than every ~20 s). Its state is newest reading
minus oldest reading in the window, so a negative value means CO₂ is
dropping.
selector:
entity:
filter:
- domain: sensor
led:
name: R PRO-1 RGB LED
description: The light entity of the R PRO-1 RGB LED.
selector:
entity:
filter:
- domain: light
beep_action:
name: Beep action
description: >-
Action(s) that make the R PRO-1 beep. Use the ESPHome action of your
device, for example `esphome.<your_device>_play_buzzer` with data
`song_str: "co2:d=8,o=6,b=180:c,p,c"`. Keep the tune short, it is
repeated at the beep interval.
default: []
selector:
action: {}
recommended_level:
name: Ventilation recommended (ppm)
description: LED turns on (yellow) at this level.
default: 1000
selector:
number:
min: 400
max: 5000
step: 50
unit_of_measurement: ppm
mode: box
needed_level:
name: Ventilation needed (ppm)
description: LED is fully red at this level.
default: 1500
selector:
number:
min: 400
max: 5000
step: 50
unit_of_measurement: ppm
mode: box
beep_level:
name: Start beeping (ppm)
description: Beeping starts at this level (unless CO₂ is dropping).
default: 2000
selector:
number:
min: 400
max: 10000
step: 50
unit_of_measurement: ppm
mode: box
min_drop:
name: Minimum drop to count as "dropping" (ppm)
description: >-
0 = any decrease stops the beeping. Raise to 5–10 if sensor jitter
makes the beeping stop and start at a plateau.
default: 0
selector:
number:
min: 0
max: 100
step: 1
unit_of_measurement: ppm
mode: box
beep_interval:
name: Beep repeat interval
default: "/30"
selector:
select:
options:
- label: Every 10 seconds
value: "/10"
- label: Every 15 seconds
value: "/15"
- label: Every 20 seconds
value: "/20"
- label: Every 30 seconds
value: "/30"
brightness:
name: LED brightness (%)
default: 60
selector:
number:
min: 1
max: 100
step: 1
unit_of_measurement: "%"
mode: slider
led_off_when_ok:
name: Turn LED off below "recommended"
description: >-
If enabled, the LED is switched off when CO₂ is below the
recommended level. Disable if you use the LED for other things.
default: true
selector:
boolean: {}
mode: queued
max: 10
max_exceeded: silent
variables:
co2_sensor: !input co2_sensor
change_sensor: !input change_sensor
rec_level: !input recommended_level
need_level: !input needed_level
beep_level: !input beep_level
min_drop: !input min_drop
led_brightness: !input brightness
led_off_when_ok: !input led_off_when_ok
triggers:
- trigger: state
entity_id: !input co2_sensor
id: reading
- trigger: time_pattern
seconds: !input beep_interval
id: beep_tick
actions:
- variables:
co2: "{{ states(co2_sensor) | float(none) }}"
change: "{{ states(change_sensor) | float(0) }}"
dropping: "{{ change < -(min_drop | float(0)) }}"
span: "{{ [need_level - rec_level, 1] | max }}"
frac: >-
{{ ([[(co2 - rec_level) / span, 0] | max, 1] | min)
if co2 is not none else 0 }}
hue: "{{ (60 * (1 - frac)) | round(0) | int }}"
- condition: template
value_template: "{{ co2 is not none }}"
- choose:
# --- LED: update on every new CO2 reading -------------------------
- conditions:
- condition: trigger
id: reading
sequence:
- choose:
- conditions:
- condition: template
value_template: "{{ co2 >= rec_level }}"
sequence:
- action: light.turn_on
target:
entity_id: !input led
data:
hs_color: "{{ [hue, 100] }}"
brightness_pct: "{{ led_brightness | int }}"
- conditions:
- condition: template
value_template: "{{ led_off_when_ok }}"
sequence:
- action: light.turn_off
target:
entity_id: !input led
# --- Buzzer: repeat while high AND not dropping -------------------
- conditions:
- condition: trigger
id: beep_tick
- condition: template
value_template: "{{ co2 >= beep_level and not dropping }}"
sequence: !input beep_action